Core composition
Discuss the core family, mineral content direction and declared classification. Specify the exact product construction; color and panel thickness alone cannot establish fire behavior.

Fire-resistant aluminum composite panels for construction projects where material selection must begin with the right core, finish and verifiable test evidence.
DERACP helps contractors, façade fabricators, architects and importers define a procurement-ready ACP specification for commercial buildings, public facilities and architectural cladding. Compare mineral-filled core options, aluminum skin gauges and exterior coatings—then request the documentation relevant to your project.

A fire-resistant aluminum composite panel uses two aluminum skins bonded around a selected core formulation. Compared with a conventional PE-core panel, an FR or mineral-rich core is formulated for improved reaction-to-fire behavior. Actual performance—and whether the product can be used in a particular building—must be established by applicable testing and the local building approval process.
Discuss the core family, mineral content direction and declared classification. Specify the exact product construction; color and panel thickness alone cannot establish fire behavior.
Choose the coating to suit exposure, appearance and maintenance. PVDF-oriented finishes are a common consideration for outdoor cladding; confirm the actual finish and coating data.
Review supporting rails, cavities, insulation, joints, barriers and fixings with the façade engineer. A compliant sheet is only one part of a potentially tested wall assembly.
The following values are DERACP-published product directions or typical project discussion points—not one universal, certified fire-rated SKU. All final specifications should match the current TDS and applicable test reports.
| Specification | DERACP reference / project option | What to verify before purchase |
|---|---|---|
| Panel thickness | Fire-related product references: 3–6 mm | Required stiffness, fabrication method and exact tested thickness |
| Aluminum skin thickness | Published fire-related options: 0.25 / 0.30 / 0.35 / 0.40 / 0.45 / 0.50 mm | Actual skin gauges of the ordered and tested panel |
| Sheet format | 1220 × 2440 mm published reference; custom sizing by agreement | Maximum width, sheet yield, tolerances and packing |
| Core selection | FR and A2-oriented directions available for discussion | Core formulation and classification for the exact panel |
| Surface finish | Project color and exterior-coating options | Finish type, color sample, UV/weathering requirements |
| Fire documentation | Request according to destination market and use | Applicable report, test method, validity, specimen and field of application |
| Order service | Sample, custom configuration, export packing discussion | MOQ, lead time, sample approval and labeling |
Important: “Fireproof” is a search and trade term, not a guarantee that any panel is noncombustible, fire-resistance-rated or suitable for all façade heights. No specific classification is claimed here for an unverified configuration.
The safest specification starts with the code requirement and traces it to a test report covering the proposed material or assembly. Different tests answer different questions.
| Term / reference | What it addresses | Procurement question |
|---|---|---|
| FR or B1-type product | Fire-retardant material direction; terminology depends on the cited standard | Which exact test method, result and panel build support the claim? |
| EN 13501-1 A2-s1,d0 | Reaction to fire, including smoke and flaming-droplet subcategories | Does the submitted classification report cover this construction and use? |
| ASTM E84 | Surface burning characteristics under a specific test method | Are the flame-spread and smoke-developed values documented? |
| NFPA 285 | Fire propagation characteristics of a tested exterior wall assembly | Is the intended wall configuration within an applicable tested assembly? |
| BS 476 references | Specific British fire-test parts, depending on project requirement | Which parts and results are required and accepted by the authority? |
A reaction-to-fire class is not the same as a fire-resistance rating in hours. Approval remains subject to the local authority, applicable code, qualified design team and matching test evidence.
Fire-related ACP is commonly evaluated for commercial façades, entrances, soffits, transport hubs, healthcare buildings, education facilities and high-occupancy interiors. Requirements vary by jurisdiction, building height, occupancy, location and wall build-up.

DERACP publishes more than 20 years of ACP manufacturing experience and offers multiple product directions, including fire-related panels, PVDF-coated exterior sheets and custom-size finishes. The advantage for B2B buyers is being able to define the order as a complete material specification.
Coordinate core direction, total panel thickness, aluminum gauge, coating, color, length and width in one technical request. This helps reduce substitution and approval risk.
Approve physical samples for gloss, metallic direction, texture and color before bulk production—especially important for large façade elevations.
Agree on dimensional checks, flatness, surface appearance, panel labeling and packaging protections in the purchase specification. Request available records for the exact order.
Discuss sheet counts, pallet configuration, protective film, shipping terms, expected production timing and the documentation package before confirming the quotation.



Share destination country, building type, height, location within the envelope and the architect's written fire criteria. Clarify material versus whole-assembly testing.
Confirm core formulation, 3–6 mm reference thickness where appropriate, skin gauges, coating, dimensions, fabrication and any required edge details.
Match reports to the proposed construction, verify validity and permissible field of application, sign off appearance samples, then finalize QC and packing conditions.
No. ACP may contain different core materials. Conventional PE-core, FR and A2-oriented products should not be treated as equivalent. The relevant performance must be demonstrated by test results for the exact proposed construction.
FR is a broad description for fire-retardant products. A2 is a defined reaction-to-fire classification in relevant systems, with smoke and droplet suffixes where applicable. Confirm the specific standard, panel build and classification report rather than relying on a sales label.
No. NFPA 285 evaluates a specific exterior wall assembly. A panel's material classification alone does not establish compliance for insulation, framing, cavities, joints and other elements of a proposed façade system.
Many projects evaluate 4 mm material, while DERACP's published fire-related references include 3–6 mm. Final thickness and aluminum skin gauges should follow engineering, fabrication needs and the tested construction.
Ask for the product TDS, detailed core and skin construction, suitable fire test or classification reports, report scope and validity, coating data, sample reference, tolerances, labeling, and agreed quality records. Obtain local professional approval where required.
DERACP publishes custom-size and finish directions. Request the required dimensions, finish and estimated quantity so availability, MOQ and compatibility with the relevant tested panel construction can be confirmed.
Tell us the destination market, fire standard or written specification, panel thickness, aluminum skin gauge, finish, sheet size, estimated square meters and delivery schedule. DERACP can discuss available constructions and the supporting documents to review before approval.
Samples, technical data and bulk order terms subject to confirmation.