Welcome!
  • English
  • Español
  • Portugues
  • Français
  • Русский
News
Current Location: Home > News

Aluminum Composite Panel Data Sheet | ACP Technical Specifications & TDS | DERACP

Update:2026/8/16 7:34:47 Views:28
DERACP technical reference for ACP / ACM specification, submittal preparation and project RFQ
ACP / ACM Technical Reference

Aluminum Composite Panel Data Sheet

Use this DERACP technical reference to compare panel construction, thickness, aluminum skin, core, coating, dimensions, finishes and documentation requirements before you approve an ACP / ACM specification or send an RFQ.

PE / PVDF / FEVE / NANO LDPE / fire-rated core options Standard & custom dimensions For facade, interior & signage
DERACP aluminum composite panel facade application
DERACP aluminum composite panel referenceActual DERACP website image
2.5–6 mmPanel thickness range referenced across DERACP product information; final availability depends on structure.
0.08–0.50 mmAluminum skin range referenced for different ACP categories; exterior projects commonly require heavier skins.
1220 × 2440Common panel format shown in DERACP product specifications, with non-standard sizes available by project discussion.
4 coating familiesDERACP publishes PE, PVDF, FEVE and NANO as available coating directions for ACP selection.
Technical Snapshot

ACP Technical Data Sheet: Configurable Product Reference

For procurement, design and submittal work, separate public product ranges from values that must be confirmed on the exact order. This reduces the risk of using a generic catalog number as a project specification.

Data fieldDERACP reference / available directionHow to use itStatus
Product familyAluminum Composite Panel (ACP) / Aluminum Composite Material (ACM)Specify the exact series by application, core and finish.Public reference
Panel structureTwo aluminum face sheets bonded to a composite core; coating and protective film vary by product.Confirm core type, surface system and reverse-side treatment for the approved construction.Project-specific
Total panel thickness2.5 mm, 3 mm and 4 mm are common published formats; selected DERACP references indicate structures up to 6 mm.Choose by stiffness, application, span, fabrication and project requirements.Published range
Aluminum skinPublished DERACP product references span approximately 0.08–0.50 mm depending on category.Do not specify skin thickness from price alone; exterior and facade work normally requires a higher structural allowance than interior or display use.Confirm by use
Common size1220 × 2440 mm appears as a common standard format.Confirm width, length, cutting tolerance and packing limits before shop drawings.Public reference
Custom dimensionsNon-standard dimensions can be discussed according to project requirements.Send nesting sizes, route/fold details and container constraints when requesting quotation.Project-specific
Coating optionsPE / PVDF / FEVE / NANOMatch coating to exposure, UV, pollution, color, gloss and maintenance expectations.Published options
Core optionsLDPE and fire-rated core directions are published by DERACP.For regulated facade work, request the exact fire classification and supporting test report for the supplied construction.Report required
Finish / colorSolid, metallic, marble, wood, brushed, glossy, mirror and custom directions.Approve physical sample / color standard before mass production where appearance control matters.Sample approval
FabricationCutting, routing, bending / folding and drilling are typical ACP processes.Confirm tooling, V-groove geometry, minimum bend rules and protective-film handling with the selected panel construction.Process-specific
Primary applicationsFacade / cladding, interior decoration, ceilings, partitions, signage, retail and display applications.Use application to drive coating, skin, core, thickness and submittal requirements.Public reference
Important: this page is a selection and RFQ reference, not a signed compliance certificate. Final values, tolerances, standards, test results and fire classification should be taken from the controlled TDS / test report for the exact DERACP construction supplied to your project.
Specification Structure

What a Professional ACP Technical Data Sheet Should Contain

A useful ACP TDS should help an architect, contractor or importer verify the product before purchase. It should also make the differences between PE-core, fire-rated, interior and exterior ACP constructions easy to audit.

1. Product Identification & Construction

  • Product name, series and intended application
  • Total panel thickness and nominal construction
  • Front and rear aluminum skin thickness
  • Aluminum alloy / temper when specified
  • Core type and core thickness
  • Adhesive / bonding system where relevant
  • Protective film identification and removal guidance

2. Dimensions & Manufacturing Tolerances

  • Standard and available panel width / length
  • Thickness tolerance
  • Width and length tolerance
  • Diagonal / squareness tolerance
  • Flatness / bow requirements
  • Edge condition and protective packaging
  • Custom-size limits for container and fabrication planning

3. Surface & Coating Data

  • PE, PVDF, FEVE, NANO or other specified surface system
  • Color reference and gloss range
  • Coating thickness where required by the project
  • Adhesion, hardness and chemical-resistance test methods
  • UV / weathering information for exterior use
  • Reverse-side coating or service coat
  • Color-tolerance / batch-control expectations

4. Mechanical, Thermal & Fire Information

  • Panel weight or density
  • Tensile / proof stress / elongation where applicable
  • Peel or bond strength where specified
  • Thermal expansion / service temperature
  • Impact / flexural data where relevant
  • Fire classification for the exact tested construction
  • Test standard, laboratory, report number and date
Submittal Logic

Do Not Treat Every PDF as the Same Document

Buyers frequently search “ACM panel specifications PDF” and receive catalogs, test reports, brochures and technical sheets mixed together. Each document answers a different procurement question.

DocumentMain purposeWhat it should answerWhen you need it
ACP Technical Data Sheet (TDS)Define measurable product configuration and technical fields.What exactly is the panel construction, size, coating, core and performance basis?Material approval, RFQ alignment, comparison and submittal.
Product Catalog / BrochurePresent product families, surfaces, applications and available choices.Which series or finish family could fit the project?Early-stage sourcing and design selection.
Color ChartCompare visual finishes and color codes.Which tone, metallic, wood, stone, brushed or mirror finish should be sampled?Design approval and physical sample request.
Fire / Compliance Test ReportDocument test conditions and classification for a tested construction.Which exact standard, sample build-up, result and report revision apply?Facade, regulated building and consultant review.
Fabrication / Installation GuideControl routing, folding, fastening, joints, handling and installation.How should the approved panel be processed and installed?Shop drawings, fabrication and site execution.
Project-Specific SubmittalBundle the documents for the exact order / specification.Does every document reference the same panel, core, coating, thickness and finish?Final approval before production or installation.
Selection by Use

Start the ACP Specification from the Application

The same phrase “aluminum composite panel” can describe very different constructions. The intended use should determine what you ask DERACP to put on the technical data sheet.

Interior

Interior Wall, Ceiling & Fit-Out

Prioritize surface consistency, clean fabrication, suitable panel thickness, PE or other agreed coating, protective film and size optimization. Fire requirements still depend on the project and local code.

Signage

Advertising & Sign Fabrication

Confirm print / bonding compatibility, flatness, cut quality, routing, panel thickness, skin thickness, finish and transport protection. Ask for a sample when brand color is important.

Exterior

Exterior Cladding & Facade

Focus on exterior-grade coating, aluminum skin, panel stiffness, movement allowance, color stability, fastening strategy, local exposure and the full facade system—not the sheet alone.

Fire-sensitive

Fire-Rated Building Applications

Do not approve from the words “FR” or “A2” alone. Request the exact tested core / panel construction, classification standard, report number, laboratory, scope and current revision.

RFQ Workflow

Five Steps from ACP TDS Search to Purchase Specification

Define use

State facade, signage, ceiling, interior wall, column, retail display or another end use.

Set build-up

Choose a starting panel thickness, aluminum skin, core and coating based on the use environment.

List approvals

Tell DERACP which fire, material, environmental or consultant documents are mandatory.

Approve finish

Confirm color code, gloss / texture and physical sample before a color-critical production run.

Lock the TDS

Align quotation, sample, purchase order and controlled technical data sheet to the same specification.

ACM Panel Specifications PDF

Need a PDF for Your Submittal Package?

You can print this live technical reference as a PDF for preliminary comparison. For project approval, request a controlled DERACP ACP technical data sheet tied to the exact panel thickness, aluminum skin, core, coating, finish and standards required by your project.

Request Official Project TDS

Recommended PDF identification

ManufacturerDERACP
Product / seriesExact construction
Project / POReference number
RevisionDate / version
Fire / testsReport IDs
ApprovalsSample + color
Product Image Display

DERACP ACP / ACM Product & Application References

The images below are hosted on the DERACP website and use short, direct /up/pic/ paths.

Buyer Checklist

Information to Send with Your ACP TDS / RFQ Request

A complete RFQ helps technical and sales teams quote the same product you intend to approve. It also reduces back-and-forth when consultants require technical documents.

Project & location

Country, city, building type, indoor / outdoor use and exposure environment.

Panel dimensions

Nominal thickness, width, length, quantity and any optimized cut sizes.

Aluminum skin

Required skin thickness or structural / application basis if not yet fixed.

Core requirement

LDPE, fire-rated direction, required classification and test-report standard.

Coating & finish

PE / PVDF / FEVE / NANO, color code, gloss, metallic / wood / mirror / other finish.

Fabrication method

Flat sheet, route-and-return cassette, bending, drilling, signage cutting or other process.

Approval documents

TDS, fire report, certificate, sample, color chart, material declaration or other submittal item.

Packing & logistics

Pallet / wooden packing, container plan, destination port and surface protection requirements.

Commercial reference

Target quantity, delivery schedule, project phase and whether OEM / private label is required.

DERACP aluminum composite panel product sheets
DERACP Specification Support

Built for Buyers Who Need More Than a Generic “4 mm ACP” Quote

DERACP specializes in aluminum composite panels and related metal composite products. Company information published on DERACP describes production in Wenzhou, Zhejiang, with a 15,000 m² factory, 5,000 m² warehouse and six production lines. For technical procurement, the practical advantage is the ability to discuss the complete panel construction—thickness, skin, core, coating, finish, size, protective film and packing—before order confirmation.

Since 2000DERACP company information states the business was founded in 2000.
6 linesPublished company information describes six production lines.
Custom specsPanel thickness, skin, core, coating, color and size can be discussed by project.
Export supportDocumentation, samples, packing and quotation can be aligned for project purchasing.
Certificates, test reports and compliance claims should always be checked against the exact product construction, issuing body, current revision and destination-market requirements before they are used for project approval.
FAQ

Aluminum Composite Panel Data Sheet Questions

What information is included in an aluminum composite panel data sheet?

A practical aluminum composite panel data sheet identifies the exact panel structure, total thickness, aluminum skin, core, coating, panel dimensions and tolerances, surface finish, fabrication-relevant information and any performance / test fields needed for the intended application. Fire or compliance claims should reference a separate current test report when required.

Can DERACP provide an ACP technical data sheet for a specific project?

DERACP can confirm project-specific technical information after you define the application, thickness, aluminum skin, core, coating, finish, dimensions, quantity and required standards or reports. For regulated projects, ask for documents that match the exact construction being quoted.

Is an ACM panel specifications PDF the same as a product catalog?

No. A catalog is useful for product families, applications and colors, but a TDS should focus on measurable technical fields. A complete submittal may also need fire reports, certificates, color approvals and fabrication / installation guidance.

What panel size is commonly available from DERACP?

DERACP product information commonly references 1220 × 2440 mm. Non-standard sizes can be discussed according to product construction and project requirements. Confirm dimensional tolerance, packing and fabrication limits on the project TDS.

What coating should I specify for exterior ACP?

Exterior projects usually require a coating selected for weather, UV and pollution exposure, such as PVDF or another suitable exterior-grade surface system. Final selection should consider the project climate, color, expected maintenance and complete panel construction.

What should I send when requesting an ACP TDS or quotation?

Send project location and application, panel thickness, aluminum skin, width / length, core type, coating, finish / color, quantity, fabrication method, destination and the exact standards, fire classifications or certificates required by the consultant, code authority or buyer.

Project-Specific Specification

Send Your ACP Requirements and Ask DERACP to Match the TDS to the Quote

Include panel thickness, aluminum skin, core, coating, color, size, quantity, application and required test documents. This gives your purchasing, technical and approval teams one specification to work from.

Request A Quote
LATEST

High Rise Aluminum Composite Panel | Fire-Safe ACP Cladding | DERACP

Specify high rise aluminum composite panel cladding for tower façades with fire-rated core options, exterior PVDF finishes, project sizes, façade engineering coordination and document-based approval from DERACP.

ACP Rainscreen Cladding | Aluminum Composite Rainscreen Panels | DERACP

Specify ACP rainscreen cladding for drained and ventilated fa?ades. Compare ACM panel build, PVDF finish, fire-core options, cassette fabrication, cavity design and project supply from DERACP.

Custom Size Aluminum Composite Panel | Custom Length & Width ACP | DERACP

Order custom size aluminum composite panels by project width and length. DERACP supports project-based ACP/ACM dimensions, coatings, cores, finishes, protective film and export packing.

Solid Color Aluminum Composite Panel | White, Black & Custom ACP | DERACP

Source solid color aluminum composite panels in white, black and custom colors. Configure ACP thickness, aluminum skin, PE/PVDF coating, core, size and packing with DERACP.

Non-Combustible Aluminum Composite Panel | A2 ACP | DERACP

Source project-specified non-combustible aluminum composite panels for A2 cladding. Compare core, aluminum skins, PVDF finish, sizes, test documents and custom options from DERACP.

Landlord hotline:
+86-021-54361792
Email:
info@der-acp.com